DTC U3000-55: Control Module - Not Configured: Action
- Using the manufacturer approved diagnostic system, check datalogger signal - Main ECU Supply Voltage (0xDD02). Refer to the electrical circuit diagrams and check the general proximity sensor module power and ground circuits for open circuit, high resistance. Repair the wiring harness as necessary
- Refer to the relevant section of the workshop manual and check the battery and charging system. Rectify as necessary