Temperature Reset Time Delay

WARNING: This page is about a different car, the 2016 Land Rover LR4, 2015 Land Rover LR4, and 2014 Land Rover LR4. However, it is still accessible from the selected car via links, so may be relevant.
In-vehicle Temperature, °C (°F)  <-15 (5) -15 to -10 (5 to 14) -10 to 0 (14 to 32) 0 to 15 (32 to 59) 15 to 25 (59 to 77) >25 (77)
Time Delay, minutes  Remains at higher temperature until manually deselected 20 15 10 5 3

To protect the heater elements, the ATC module disables front seat heating if battery voltage exceeds 16.5 ± 0.3 V for more than 5 seconds. Front seat heating is re-enabled when battery voltage decreases to 16.2 ± 0.3 V.

The ATC module monitors the power feeds to the heater elements and disables the applicable front seat heating if a short or open circuit is detected. The ATC module also disables seat heating if the seat temperature rises significantly above the target temperature setting.

The plausibility of the temperature sensor inputs is also monitored by the ATC module. When seat heating is selected, if one of the temperature sensor inputs is within 5 °C (9 °F) below the target temperature, the ATC module monitors the sensor input for a temperature increase and checks that it is between the minimum and maximum working temperatures. If a temperature sensor input is at the high end of the working range, while the ambient air temperature and the engine temperature are within 10 °C (18 °F) of each other, the ATC module disables front seat heating until the input decreases below the target temperature setting. The ATC module interprets a temperature sensor input value of -45 °C (-49 °F) or below as an open circuit, and temperature sensor input value of 100 °C (212 °F) or more as a short circuit.