Temperature Control
ATC ECU supplies battery voltage to temperature servos to set position of blend air flaps in heater unit. To change drive direction, ATC ECU reverses polarity of battery voltage. ATC ECU determines required position of blend air flaps based on ambient air temperature, target temperatures and fresh/recirculated air selection.