Component Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
ATS (component side) | 1 (signal) | ATS (component side) | 2 (ground) | Table below |
AMBIENT AIR TEMPERATURE SENSOR SPECIFICATION
| Temperature [°C (°F)] | Resistance (kΩ) | Temperature [°C (°F)] | Resistance (kΩ) |
|---|---|---|---|
| -10 (14) | 158.18 | 10 (50) | 58.80 |
| 0 (32) | 95.10 | 20 (68) | 37.32 |
Good
- Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the ATS and Go to "VERIFICATION OF REPAIR " procedure.