Component Inspection
- Check the intake air temperature with the KDS.
- Disconnect the Manifold Absolute Pressure Sensor & Intake Air Temperature Sensor (MAPS & IATS) connector.
(Refer to Removal And Installation
- Measure resistance after disconnecting the MAPS & IATS connector.
Terminal Function 2 ( - ) 4 ( + ) Pressure Output Voltage (V) kPa kg/cm2 psi 10 0.1 1.45 0.5 20 0.2 2.90 0.881 30 0.3 4.35 1.262 40 0.4 5.80 1.643 50 0.5 7.25 2.024 60 0.6 8.70 2.405 70 0.7 10.15 2.786 80 0.8 11.60 3.167 100 1.0 14.50 3.929 115 1.17 16.67 4.5