Component Inspection
| Inspection Condition | (+) Probe | (-) Probe | Reference | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
ECTS #2 (component side) | 1 (signal) | ECTS #2 (component side) | 2 (ground) | Table1 |
ENGINE COOLANT TEMPERATURE SENSOR RESISTANCE OF SPECIFICATION
| Temperature | Resistance (kΩ) | Temperature | Resistance (kΩ) | ||
|---|---|---|---|---|---|
| °C | °F | °C | °F | ||
| -40 | -40 | 41.74 ~ 54.54 | 20 | 68 | 0.56 ~ 0.61 |
| -20 | -4 | 14.13 to 16.83 | 40 | 104 | 0.31 ~ 0.33 |
| -10 | 14 | 8.39 ~ 10.22 | 60 | 140 | 0.56 ~ 0.61 |
| 0 | 32 | 2.31 to 2.59 | 80 | 176 | 0.31 ~ 0.33 |
| 10 | 50 | 3.42 ~ 4 | 100 | 212 | 0.18 ~ 0.19 |
Good
- Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the ECTS #2 and Go to "VERIFICATION OF REPAIR " procedure.