Repair Procedures: Replacement
- Discharge refrigerant from the refrigeration system.
- Replace faulty tube or hose.CAUTION: Cap the open fittings immediately to keep moisture or dirt out of the system.
- Tighten the bolt or nut joint to the specified torque.CAUTION: Connections should not be torque tighter than the specified torque.
- Evacuate air in the refrigeration system and charge system with refrigerant.
Specified amount
550 ± 25g (19.4 ± 0.88oz.)
- Inspect for leakage of refrigerant.
Using a gas leak detector, check for refrigerant leakage.
- Inspect A/C operation.