Repair Procedures: Replacement
- Disconnect the negative (-) battery terminal.
- Recover the refrigerant with a recovery/charging station.
- Disconnect the A/C pressure transducer connector (A).
- Remove the A/C pressure transducer (B).
Tightening torque :
10 ~ 12 N.m (1.02 ~ 1.22 kgf.m, 7.4 ~ 8.8 lb-ft)
CAUTION: Be careful not to bend the liquid & suction pipe. - Install in the reverse order of removal.NOTE: When installing, replace it with a new O-ring (A).