Control Circuit Inspection
■ Check Short To Ground In Harness
- IG "OFF" and disconnect VIS connector.
- IG "ON"
- Measure voltage between control terminal of VIS harness connector and chassis ground.
Specification: Approx. 3.5V
- Is the measured voltage within specification?
YES
- Go to "Component Inspection " procedure.
NO
- Repair open or short to ground in harness, and go to "Verification Of Vehicle Repair " procedure.