Control Circuit Inspection
■ Check Open Or Short In FPR Circuit
- IG KEY "OFF".
- Disconnect FPR connector.
- IG KEY "ON" & ENG "OFF"
- Measure the voltage between FPR open, FPR close terminal of FPR harness connector and chassis ground.
Specification:
FPR open Terminal: Approx. 0~0.6V
FPR close Terminal: Approx. 0.6V
- Is the measured voltage within specification?
YES
- Go to "Component Inspection " procedure.
NO
- Check for Open or Short in FPR circuit. Repair as necessary and then go to "Verification Of Vehicle Repair " procedure.