DTC Information: DTC Detecting Condition

Item Detecting Condition Possible cause
DTC Strategy
  • Voltage Monitoring
  1. Open or short of power supply circuit (ABS1)
  2. Faulty HECU
Case 1 Monitoring Period
  • Continuously
Enable Conditions
  • A failure is detected if supply voltage under 7.0V at the pump motor is continued over 300ms.
    • Stop ABS/ESP (ESC) control immediately, permit EBD control partially
Case 2 Monitoring Period
  • Only for motor relay on
Enable Conditions
  • A failure is detected if voltage at pump motor does not go up to over (3.0±0.5)V within 80ms after motor relay on, or voltage at the pump motor is under (battery voltage - 4.0V) for more than 500ms.
    • Stop ABS/ESP (ESC) control immediately, permit EBD control partially
Case 3 Monitoring Period
  • Only for motor relay off
Enable Conditions
  • A failure is detected if voltage at pump motor is over (3.0±0.5)V for more than 2.5s
    • Stop the ABS/ESP (ESC) control immediately when found in uncontroled status, prohibit control after finishing control when found in controlled status
Case 4 Monitoring Period
  • Only for motor relay On->Off
Enable Conditions
  • ECU monitors if voltage at pump motor is on the high-Level during some time (TSL). The TSL is calculated by voltage at ECU and duty ratio function about motor operation. The duration for Low level of motor voltage should be under 40ms for TSL. Motor should be operated maximum three times when duration is over 40ms. The monitoring detect a failure if it is still over 40ms after that
    • Stop ABS/ESP (ESC) control immediately, permit EBD control partially
Fail Safe
  • The ABS/ESP (ESC) functions are inhibited
  • The ABS/ESP (ESC) warning lamps are activated