Ground Circuit Inspection
■ Check open in harness
- IG "OFF". Disconnect OTS connector and then IG "ON".
- Measure voltage between signal terminal of OTS harness connector and chassis ground. (Measurement "A")
- Measure voltage between signal and ground terminals of OTS harness connector. (Measurement "B")
Specification: Voltage difference between measurement "A" and "B" is below 200mV.
- Is the measured voltage within specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair contact resistance or open in harness. Go to "VERIFICATION OF VEHICLE REPAIR " procedure.