Repair procedures: Replacement
- Disconnect the battery negative terminal first, then the positive terminal.
- Disconnect the alternator connector, and remove the cable from alternator "B" terminal.
- Remove the drive belt.
- Remove the compressor. Refer to REPAIR PROCEDURES .
- Pull out the through bolt and then remove the alternator (A).
Tightening torque :
49.0 ~ 63.7N.m (5.0 ~ 6.5kgf.m, 36.2 ~47.0lb-ft)
- Installation is the reverse order of removal.