Component Inspection
WARNING: This page is about a different variant/trim than selected.
- Connect a scan tool on Data Link Connector (DLC).
- Check MAPS output voltage at idle and IG ON.
VOLTAGE SPECIFICATION
| Condition |
Output Voltage (V) |
| Idle |
0.8-1.6 |
| IG ON |
3.9-4.1 |