DTC C2402 Motor-Electrical: DTC Detecting Condition
DTC DETECTING CONDITION CHART
| Item |
Detecting Condition |
Possible cause |
| DTC strategy |
|
- Open or short of power supply circuit (ABS1)
- Inoperative HECU
|
| Case1 (Stop monitor) |
Monitoring Period |
- Stop monitor is active if the pump is off i.e. not actuation and no Slowdown.
|
| Enable Conditions |
- A failure is detected if the pump motor voltage > 2.0 V for more than 1 s.
|
| Fail Safe |
- The return pump does not work correct.
- The ABS/ESC functions are inhibited, reduced function of the EBD system.
- The ABS/EBD/ESC warning lamps are activated.
|
| Case2 (Pump run monitor) |
Monitoring Period |
- The monitor is active if the pump is switched on
|
| Enable Conditions |
- A failure is detected if the pump motor voltage < (battery voltage - 4.0 V) for more than 100ms.
|
| Fail Safe |
- Pressure decrease (outlet valve) is no longer possible.
- The ABS/ESC functions are inhibited, reduced function of the EBD system.
- The ABS/EBD/ESC warning lamps are activated.
|
| Case3 (Pump slowdown monitor) |
Monitoring Period |
- Monitor is always active in the transition "pump on → pump off"
|
| Enable Conditions |
- After the end of the actuation of the motor relay has, the pump motor is still in motion and is generating a Voltage during it.s slowdown. The generated UM is monitored for a certain time on high level. The time depends on the supply voltage and is in the range of t = 30 ms to t = 125 ms. If the slow down condition isn't met, the pump is activated again (see actuation times below) and the slowdown time is measured again. This is repeated for maximum n = 3 times. If, after the last pump activation, the pump motor slowdown time is still to short, a failure is detected. Actuation times:
1st actuation: 200 ms
2nd actuation: 1000 ms
3rd actuation: 3000 ms
|
| Fail Safe |
- Pressure decrease (outlet valve) is no longer possible.
- The ABS/ESC functions are inhibited, reduced function of the EBD system.
- The ABS/EBD/ESC warning lamps are activated.
|