A/T Control Relay Check
- Remove the A/T control relay.
- Use jumper wires to connect A/T control relay terminal 2 to the battery (+) terminal and terminal 4 to the battery (-) terminal.
- Check the continuity between terminal (1) and terminal (3) of the A/T control relay when the jumper wires are connected to and disconnected from the battery.
- If there is a problem, replace the A/T control relay.