ETACS Function
- Variable intermittent wiper time specification:
- T1: Max. 0.3 sec.
- T2: Time of wiper motor 1 rotation (0.6-0.8 sec.)
- T3: 2.2+/-0.2 sec. (VR=0 k ohms)-10.0+/-1.0 sec. (VR=50 k ohms)
- Washer related wiper time specification:
- T1: 0.6 sec.
- T2: 2.5-3.8 sec.NOTE: This function should be operated preferentially even though the variable intermittent wiper is operating.
- Rear window defogger time specification:
- T1: 60m sec.
- T2: 20 +/- 1 Min.
- Seat belt warning time specification:
- T1: 6 +/- 1 sec.
- T2: 0.45 +/- 0.1 sec.
- T3: 0.3 +/- 0.1 sec.
- Ignition key hole illumination time specification:
- T1: 10 +/- 1.0 sec.
- T2: 0 - 10 sec.
- Delayed out room lamp time specification: T1: 5.5 +/- 0.5 sec.
- Key operated warning time specification: T1, T2: 0.45 +/- 0.1 sec.
- Ignition key reminder time specification:
- T1: 0.5 sec.
- T2: 0-0.5 sec.
- Outside Door key illumination (without burglar alarm) time specification: T1: 10 +/- 1.0 sec.
- Power window timer time specification: T1: 30 +/- 5 sec.
- Central door lock/unlock (without burglar alarm) time specification: T: 0.5 +/- 0.1 sec.
- Central door lock/unlock (with burglar alarm): :
- Time specification when using the door key: T: 0.5 +/- 0.1 sec.
- Time specification when using the door lock knob switch: T: 0.5 +/- 0.1 sec.
- Time specification when using the transmitter (TX): T: 0.5 +/- 0.1 sec.
- Time specification, power window main door lock switch: T: 0.5 +/- 0.1 sec.
- Tail lamp auto cut
- Time specification, two-turn unlock: T1: 3 +/- 0.5 sec.