ETACS Function

  1. Variable intermittent wiper
    1. Time specification
    2. T1: Max. 0.3 sec.
    3. T2: Time of wiper motor 1 rotation (0.6~0.8 sec.).
    4. T3: 2.2 +/- 0.2 sec. (VR=0 kΩ)~10.0 +/- 1.0 sec. (VR=50 kΩ)
    Fig 1: Variable Intermittent Wiper Time Specification
    G01093819
  2. Washer related wiper
    1. Time specification
      1. T1: 0.6 sec.
      2. T2: 2.5~3.8 sec.
    2. This function should be operated preferentially even though the variable intermittent wiper is operating.
    Fig 2: Washer Related Wiper Time Specification
    G01093820
  3. Rear window defogger
    1. Time specification
    2. T1: 60m sec.
    3. T2: 20 +/- 1 Min.
    Fig 3: Rear Window Defogger Time Specification
    G01093821
  4. Seat belt warning
    1. Time specification
    2. T1: 6 +/- 1 sec.
    3. T2: 0.45 +/- 0.1 sec.
    4. T3: 0.3 +/- 0.1 sec.
    Fig 4: Seat Belt Warning Time Specification
    G01093822
  5. Ignition key hole illumination
    1. Time specification
    2. T1: 10 +/- 1.0 sec.
    3. T2: 0 - 10 sec.
    Fig 5: Ignition Key Hole Illumination Time Specification
    G01093823
  6. Delayed out room lamp
    1. Time specification
    2. T1: 5.5 +/- 0.5 sec.
    Fig 6: Delayed Out Room Lamp Time Specification
    G01093824
  7. Key operated warning
    1. Time specification
    2. T1, T2: 0.45 +/- 0.1 sec.
    Fig 7: Key Operated Warning Time Specification
    G01093825
  8. Ignition key reminder
    1. Time specification
    2. T1: 0.5 sec.
    3. T2: 0~0.5 sec.
    Fig 8: Ignition Key Reminder Time Specification
    G01093826
  9. Outside Door key illumination (Without burglar alarm)
    1. Time specification
    2. T1: 10 +/- 1.0 sec.
    Fig 9: Outside Door Key Illumination (Without Burglar Alarm) Time Specification
    G01093827
  10. Power window timer
    1. Time specification
    2. T1: 30 +/- 5 sec.
    Fig 10: Power Window Timer Time Specification
    G01093828
  11. Central door lock/unlock (without burglar alarm)
    1. Time specification
    2. T: 0.5 +/- 0.1 sec.
    Fig 11: Central Door Lock/Unlock (Without Burglar Alarm) Time Specification
    G01093829
  12. Central door lock/unlock (with burglar alarm)
    1. When using the door key
      1. Time specification
      2. T: 0.5 +/- 0.1 sec.
      Fig 12: Central Door Lock/Unlock (With Burglar Alarm) Time Specification
      G01093830
    2. When using the door lock knob switch
      1. Time specification
      2. T: 0.5 +/- 0.1 sec.
      Fig 13: When Using The Door Lock Knob Switch Time Specification
      G01093831
    3. When using the transmitter (TX)
      1. Time specification
      2. T: 0.5 +/- 0.1 sec.
      Fig 14: When Using The Transmitter (TX) Time Specification
      G01093832
    4. Power window main door lock switch
      1. Time specification
      2. T: 0.5 +/- 0.1 sec.
    Fig 15: Power Window Main Door Lock Switch Time Specification
    G01093833
  13. Tail lamp auto cut
    Fig 16: Tail Lamp Auto Cut
    G01093834
  14. Two-Turn unlock
    1. Time specification
    2. T1: 3 +/- 0.5 sec.
    Fig 17: Two-Turn Unlock Time Specification
    G01093835