ETACS Function
- Variable intermittent wiper
- Time specification
- T1: Max. 0.3 sec.
- T2: Time of wiper motor 1 rotation (0.6~0.8 sec.).
- T3: 2.2 +/- 0.2 sec. (VR=0 kΩ)~10.0 +/- 1.0 sec. (VR=50 kΩ)
- Washer related wiper
- Time specification
- T1: 0.6 sec.
- T2: 2.5~3.8 sec.
- This function should be operated preferentially even though the variable intermittent wiper is operating.
- Rear window defogger
- Time specification
- T1: 60m sec.
- T2: 20 +/- 1 Min.
- Seat belt warning
- Time specification
- T1: 6 +/- 1 sec.
- T2: 0.45 +/- 0.1 sec.
- T3: 0.3 +/- 0.1 sec.
- Ignition key hole illumination
- Time specification
- T1: 10 +/- 1.0 sec.
- T2: 0 - 10 sec.
- Delayed out room lamp
- Time specification
- T1: 5.5 +/- 0.5 sec.
- Key operated warning
- Time specification
- T1, T2: 0.45 +/- 0.1 sec.
- Ignition key reminder
- Time specification
- T1: 0.5 sec.
- T2: 0~0.5 sec.
- Outside Door key illumination (Without burglar alarm)
- Time specification
- T1: 10 +/- 1.0 sec.
- Power window timer
- Time specification
- T1: 30 +/- 5 sec.
- Central door lock/unlock (without burglar alarm)
- Time specification
- T: 0.5 +/- 0.1 sec.
- Central door lock/unlock (with burglar alarm)
- When using the door key
- Time specification
- T: 0.5 +/- 0.1 sec.
- When using the door lock knob switch
- Time specification
- T: 0.5 +/- 0.1 sec.
- When using the transmitter (TX)
- Time specification
- T: 0.5 +/- 0.1 sec.
- Power window main door lock switch
- Time specification
- T: 0.5 +/- 0.1 sec.
- Tail lamp auto cut
- Two-Turn unlock
- Time specification
- T1: 3 +/- 0.5 sec.