Adjustment (A/T)
- Disconnect TP sensor connector. Connect ohmmeter between TP sensor connector terminals No. 1 (E) and No. 2 (IDL). See Figure . Loosen TP sensor attaching screws.
- Insert a .010" (.25 mm) feeler gauge between throttle lever and throttle stop screw. Rotate TP sensor clockwise about 30 degrees, then rotate counterclockwise until ohmmeter indicates continuity.
- Remove feeler gauge. Insert a .016" (.40 mm) feeler gauge between throttle lever and throttle stop screw. If ohmmeter indicates no continuity, go to next step. If ohmmeter indicates continuity, repeat adjustment procedure.
- Tighten TP sensor attaching screws. Open throttle valve fully and verify resistance between terminals No. 1 (E) and No. 3 (Vt) is about 5000 ohms.