Flash: Radio Frequency Hub Module (RFHM) Updates (08-150-25)

WARNING: This page is about the Gladiator High Tide, Full Time T/Case Control, Automatic Trans, which is a different variant/trim than selected.
Publication date: 2025-05-09
Reference number: 08-150-25

FLASH: RADIO FREQUENCY HUB MODULE (RFHM) UPDATES

FLASH: RADIO FREQUENCY HUB MODULE (RFHM) UPDATES

TECHNICAL SERVICE BULLETIN

Reference Number(s): 08-150-25, Date of Issue:  May 09, 2025
CHRYSLER: 2024 (JT) Jeep Gladiator
GROUP: 08 - Electrical

VEHICLES AFFECTED

2024 (JT) Jeep Gladiator 

CUSTOMER SYMPTOM

Customers must experience the following: 

Software enhancement includes: 

CAUSE

RFHM software 

REPAIR SUMMARY

This bulletin involves updating the RFHM module with the latest available software.

CLAIMS DATA

CLAIMS INFORMATION

Labor Operation No: Labor Description Skill Category Labor Time
18-19-12-BB Module, Radio Frequency Hub (RFHM) - Reprogram (0 - Introduction) 6 - Electrical and Body Systems 0.3 Hrs.
Failure Code CC Customer Concern  

The dealer must use failure code CC with this Technical Service Bulletin. 

SPECIAL TOOLS/EQUIPMENT

SPECIAL TOOLS INFORMATION

Description Ref. No. Notes
wiTECH or Equivalent - -

DIAGNOSIS

Using a Scan Tool (wiTECH) with the appropriate Diagnostic Procedures available in DealerCONNECT/Service Library, verify all related systems are functioning as designed. If Diagnostic Trouble Codes (DTCs) or symptom conditions, other than the ones listed above are present, record the issues on the repair order and repair as necessary before proceeding further with this bulletin.

If the customer describes any of the symptoms listed above in the customer symptom section, perform the Repair Procedure.

REPAIR PROCEDURE

NOTE: Install a battery charger to ensure battery voltage does not drop below 13.2 volts. Do not allow the charging voltage to climb above 13.5 volts during the flash process.
NOTE: If this flash process is interrupted/aborted, the flash should be restarted.
  1. Reprogram the RFHM with the latest available software. If issues arise when flashing a module using the wiTECH Diagnostic Application, please submit a ticket to the Helpdesk. The helpdesk can be found within the Help menu.
  2. Clear all DTCs that may have been set in any module due to reprogramming. The wiTECH application will automatically present all DTCs after the flash and allow them to be cleared.

POLICY

Reimbursable within the provisions of the warranty.