Box, MOPAR Connect TELEMATIC - LHD
- Before installation, make a note of the data on the label at of the control module. This data will be needed for the test procedure at the end of the installation.
- Apply a strip of bi-adhesive Velcro to the back of the T-box module.
- Apply the Coroplast covering tape to the parts of the T-box module in contact with the vehicle to prevent vibration noise when it is mounted on the vehicle.
- Inspect the T-box wiring for Coroplast tape (2) covering up to the electrical connector. Add Coroplast tape as needed.
- Clean the contact surface (1) with isopropyl alcohol or heptane where the module will be fitted.
- Position the control module (1a) on the bracket with the connector socket facing upwards, and secure it with double-sided adhesive tape and two cable ties (1b). Pass the cable ties through the slots in the bracket.
- Connect the wiring connector (1a) to the control module (1b).
- Install the glove box. Refer to GLOVE BOX, INSTRUMENT PANEL, INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
- On completion of installation of the T-box module, connect the diagnosis instrument to the car's OBD II socket, locate the BCM module and check for errors.