Theory Of Operation
The purpose of the diagnostic is to detect circuit failures on any of the output stages. All output stages are controlled by a current controller that Controller Area Network (CAN) operate an output stage in two different modes:
- Current controlled mode (pressure regulators)
- Switched mode or Pulse Width Modulated (PWM) controlled (solenoids)
Pressure Regulator Monitoring: The current regulator Application-Specific Integrated Circuit (ASIC) in the Transmission Control Module (TCM) indicates the following circuit failures via Serial Peripheral Interface (SPI) bus to the Central Processing Unit (CPU):
- Short to ground
- Short to battery or open circuit
Solenoid Monitoring: The TCM measures the actual solenoid voltages and compares them to calibrated thresholds to identify the following electrical failures:
- Short to ground or open circuit
- Short to battery