Pump-Natural Vac Leak Detection: Installation
| 1 - FUEL PUMP MODULE LOCK RING | 4 - EVAP CANISTER |
| 2 - FUEL PUMP MODULE | 5 - NVLD PUMP |
| 3 - ISOLATOR SLEEVE | 6 - FUEL TANK |
- Install NVLD pump (5) to mounting bracket (snaps on).
- Carefully install vapor/vacuum lines to NVLD pump. The vapor/vacuum lines and hoses must be firmly connected. Check the vapor/vacuum lines at the NVLD pump, filter and EVAP canister purge solenoid for damage or leaks. If a leak is present, a Diagnostic Trouble Code (DTC) may be set.
- Connect electrical connector to pump.
- If equipped, install fuel tank skid plate.