Climate Control System Odor (JTB00311NAS1)
Publication date: 2013-09-26Reference number: JTB00311NAS1
CLIMATE CONTROL SYSTEM ODOR
TECHNICAL SERVICE BULLETIN
Reference Number(s): JTB00311NAS1, Date of Issue:
September 26, 2013
| JAGUAR: | 2012 Onwards XF (X250), XJ Range (X351), XK Range (X150); 2014 Onwards F-TYPE (X152) |
| SECTION: | 412-03 |
| VIN: | S59096 Onwards; V39036 Onwards; B49778 Onwards; K00222 Onwards |
AFFECTED VEHICLE RANGE
XF (X250)
Model Year: 2012 Onwards
VIN: S59096 Onwards
XJ Range (X351)
Model Year: 2012 Onwards
VIN: V39036 Onwards
XK Range (X150)
Model Year: 2012 Onwards
VIN: B49778 Onwards
F-TYPE (X152)
Model Year: 2014 Onwards
VIN: K00222 Onwards
MARKETS
USA
CONDITION SUMMARY
Situation: An odor may be present when the Climate Control System is switched 'ON'.
Cause: This may be caused by mold spore accumulation/build-up in the evaporator core.
Action: Should a customer express this concern, follow the Service Instruction outlined below.
PARTS
PARTS INFORMATION
| C2D22759 | Evaporator core - XF, XJ | Quantity: 1 |
| C2P23642 | Evaporator core - F-TYPE, XK | Quantity: 1 |
TOOLS
Refer to Workshop Manual for any required special tools.
WARRANTY
NOTE:
Repair procedures are under constant review, and therefore times are subject to change; those quoted here must be taken as guidance only. Always refer to TOPIx to obtain the latest repair time.
NOTE:
DDW requires the use of causal part numbers. Labor only claims must show the causal part number with a quantity of zero.
WARRANTY INFORMATION
| DESCRIPTION | SRO | TIME (HOURS) | CONDITION CODE | CAUSAL PART |
|---|---|---|---|---|
| Evaporator core - Renew - F-TYPE | 82.25.20 | 6.0 | 49 | C2P8713 |
| Evaporator core - Renew - XF | 82.25.22 | 6.6 | 49 | C2Z6527 |
| Evaporator core - Renew - XJ | 82.25.20 | 10.5 | 49 | C2Z6527 |
| Evaporator core - Renew - XK N/A | 82.25.20 | 4.4 | 49 | C2P8713 |
| Evaporator core - Renew - XK SC | 82.25.20 | 4.5 | 49 | C2P8713 |
NOTE:
Normal Warranty policies and procedures apply.
SERVICE INSTRUCTION
NOTE:
Prior to installation of new evaporator core, wash out the evaporator core housing with warm water to remove any mold spore accumulation.
- Replace the evaporator core (see TOPIx Workshop Manual, Section 412-03).