Conditions for Setting the DTC
The control module determines that the difference between the AIR pressure sensor and the BARO sensor signals is greater than 10 kPa when the AIR pump is commanded OFF.
OR
The control module determines that the difference between the AIR pressure sensor and the BARO sensor signals is greater than 50 kPa when the AIR pump is commanded ON.