Conditions For Setting DTC
- Engine is running above 500 RPM for more than 10 seconds.
- System voltage is between 11.5 to 16.0 volts.
- MAF sensor signal frequency is above 40 g/s, for a total of 50 percent of the last 1000 samples monitored. A sample is taken every cylinder event.