Diagnostic Aids
Check oxygen sensor pigtail wire for breaks and contamination. An intermittent problem can be caused by misrouted harness, rubbed through wire insulation or broken wire inside insulation. Check for intermittent open in HO2S 2 signal circuit wire. DO NOT attempt to repair damaged oxygen sensor connector or wiring. If damage is detected, replace oxygen sensor.