Diagnosis Procedure
- PERFORM INITIALIZATION PROCEDURE
Initialization procedure is performed and operation is confirmed.
Refer to Work Procedure . Is the inspection result normal?
YES>>
INSPECTION END
NO>>
GO TO 2.
- CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (DOOR KEY CYLINDER SWITCH)
Check front door lock assembly (driver side) (door key cylinder switch).
Refer to Component Function Check . Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace the malfunctioning parts.
- CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES>>
Check intermittent incident. Refer to Inspection .
NO>>
GO TO 1.