Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn A/C switch and blower fan switch OFF.
- Turn ignition switch OFF.
- Check ground connection E191. Refer to Ground Inspection in Inspection .
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace ground connection.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.
Refrigerant pressure sensor Ground Voltage (V) Connector Terminal E162 3 Ground Approx. 5
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
GO TO 3.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E162 3 F142 136 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
Check sensor power supply 2 circuit. Refer to Diagnosis Procedure .
NO>>
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E162 1 F142 125 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E162 2 F142 108 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
GO TO 6.
NO>>
Repair or replace error-detected parts.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- CHECK INTERMITTENT INCIDENT
Refer to Inspection . Is the inspection result normal?
YES>>
Replace refrigerant pressure sensor. Refer to CONDENSER : Exploded View .
NO>>
Repair or replace error-detected parts.