DTC Diagnosis Procedure
- CHECK BATTERY CURRENT SENSOR POWER SUPPLY CIRCUIT-I
- Disconnect battery current sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between battery current sensor harness connector and ground.
Battery current sensor
Ground
Voltage (V)
Connector
Terminal
E63
2
Ground
Approx. 5
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure .
Is inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK BATTERY CURRENT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between battery current sensor harness connector and ECM harness connector.
Battery current sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
4
F91
43
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between battery current sensor and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK BATTERY CURRENT SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between battery current sensor harness connector and ECM harness connector.
Battery current sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
3
F91
38
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 7.
NO
GO TO 6.
- Check the continuity between battery current sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between battery current sensor and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK BATTERY CURRENT SENSOR
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 8.
NO
Replace battery negative cable assembly.
- CHECK INTERMITTENT INCIDENT
Refer to Inspection .
INSPECTION END