Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Infiniti >> 2021 >> Q60 Pure, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (DTCS) (7 Of 7) >> Engine (ECM) >> DTC P2586: WASTEGATE Control Valve Position Sensor >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

  1. CHECK WASTEGATE CONTROL VALVE POSITION SENSOR POWER SUPPLY 
    1. Turn ignition switch OFF.
    2. Disconnect electric wastegate control actuator (bank 2) harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between electric wastegate control actuator (bank 2) harness connector and ground.

      +

      -

      Voltage

      (Approx.)

      Electric wastegate control actuator (bank 2)

      Connector

      Terminal

      F138

      3

      Ground

      5 V

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    GO TO 2.

  2. CHECK WASTEGATE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between electric wastegate control actuator (bank 2) harness connector and ECM harness connector.

      Electric wastegate control actuator (bank 2)

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      F138

      3

      F142

      136

      Existed

    4. Also check harness for short to power and short to ground.

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace error-detected parts.

  3. CHECK SENSOR POWER SUPPLY 2 CIRCUIT 

    Refer to Diagnosis Procedure .

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace error-detected parts.

  4. CHECK WASTEGATE CONTROL VALVE POSITION SENSOR GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between electric wastegate control actuator (bank 2) harness connector and ECM harness connector.

      Electric wastegate control actuator (bank 2)

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      F138

      2

      F142

      125

      Existed

    4. Also check harness for short to power.

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Repair or replace error-detected parts.

  5. CHECK WASTEGATE CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT 
    1. Check the continuity between electric wastegate control actuator (bank 2) harness connector and ECM harness connector.

      Electric wastegate control actuator (bank 2)

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      F138

      1

      F142

      120

      Existed

    2. Also check harness for short to power and short to ground.

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    Repair or replace error-detected parts.

  6. CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR (BANK 2) 

    Check the electric wastegate control actuator (bank 2). Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace turbocharger assembly [do not replace electric wastegate control actuator (bank 2) only]. Refer to TURBOCHARGER : Removal & Installation .