DTC Diagnosis Procedure
- CHECK THE DTC
If P0102 and P0113 are detected at the same time, check power supply and ground circuit of the MAF sensor.
Is applicable DTC detected?
YES
Perform the diagnosis for power supply and ground circuit of the mass air flow sensor. GO TO 3.
NO
GO TO 2.
- CHECK HARNESS CONNECTOR
- Disconnect MAF sensor harness connector and ECM harness connector.
- Connect MAF sensor harness connector and ECM harness connector.
- Perform DTC Confirmation Procedure. Refer to Confirmation Procedure .
Is DTC detected?
YES
GO TO 3.
NO
INSPECTION END
- CHECK INTAKE AIR TEMPERATURE SENSOR 1 POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect mass air flow (MAF) sensor (intake air temperature sensor 1 is built-into) harness connector.
- Turn ignition switch ON.
- Check the voltage between mass air flow sensor (bank 1) harness connector and ground.
+
-
Voltage
(Approx.)
MAF sensor (bank 1)
Connector
Terminal
F99
4
Ground
5 V
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK INTAKE AIR TEMPERATURE SENSOR 1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between mass air flow sensor (bank 1) harness connector and ECM harness connector.
MAF sensor (bank 1)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F99
4
F143
43
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Perform trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK INTAKE AIR TEMPERATURE SENSOR 1 GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between mass air flow sensor (bank 1) harness connector and ECM harness connector.
MAF sensor (bank 1)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F99
3
F143
30
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK ECM GROUND CIRCUIT
- Check the continuity between ECM harness connector and ground.
ECM
--
Continuity
Connector
Terminal
F143
3
Ground
Existed
F142
87
88
E152
199
201
204
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- Check the continuity between ECM harness connector and ground.
- CHECK INTAKE AIR TEMPERATURE SENSOR 1
Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END.
NO
Replace mass air flow sensor (bank 1) (with intake air temperature sensor 1). Refer to AIR CLEANER AND AIR DUCT : Exploded View .