How To Set
With CONSULT
Perform "TARGET EVAPORATOR TEMP UPPER LIMIT SETTING" in "WORK SUPPORT" mode of "HVAC" using CONSULT.
|
Work support items |
Display |
Setting |
|
TARGET EVAPORATOR TEMP UPPER LIMIT SETTING |
Initial setting |
Setting 1 |
|
Low |
Setting 4 |
|
|
Middle (initial status) |
Setting 3 |
|
|
High |
Setting 2 |
|
Setting |
Target evaporator temperature upper limit value |
Evaporator freezing protection control |
Refrigerant discharge amount control |
|
Setting 1 |
10 deg.C (50 deg.F) |
Minimum operation ratio of compressor |
Minimum refrigerant discharge amount |
|
Setting 2 |
7 deg.C (45 deg.F) |
Operation ratio of compressor increases from setting 1. |
Refrigerant discharge amount increases from setting 1. |
|
Setting 3 |
5 deg.C (41 deg.F) |
Operation ratio of compressor increases from setting 2. |
Refrigerant discharge amount increases from setting 2. |
|
Setting 4 |
3 deg.C (37 deg.F) |
Operation ratio of compressor increases from setting 3. |
Refrigerant discharge amount increases from setting 3. |