Diagnosis Procedure
- CHECK POWER WINDOW MAIN SWITCH OUTPUT SIGNAL
- Turn ignition switch ON.
- Check signal between left front door control unit harness connector and ground using oscilloscope.
(+)
(-)
Condition
Voltage
(approx.)
Left front door control unit
Connector
Terminal
D16
41
Ground
Front power window LH
Operating
12 V
Other than above
Is the inspection result normal?
YES
INSPECTION END.
NO
GO TO 2.
- CHECK POWER WINDOW MAIN SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect power window main switch connector and left front door control unit connector.
- Check continuity between power window main switch harness connector and left front door control unit harness connector.
Power window main switch
Left front door control unit
Continuity
Connector
Terminal
Connector
Terminal
D38
1
D16
41
Existed
- Check continuity between power window main switch harness connector and ground.
Power window main switch
Ground
Continuity
Connector
Terminal
D38
1
Not existed
Is the inspection result normal?
YES
Replace power window main switch. Refer to Removal and Installation .
NO
Repair or replace harness.