Diagnosis Procedure
- CHECK POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect power window main switch connectors.
- Turn ignition switch ON.
- Check voltage between power window main switch harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Power window main switch Connector Terminal D5 9 Ground 12 4
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Check continuity between BCM harness connector and power window main switch harness connector.
BCM Power window main switch Continuity Connector Terminal Connector Terminal M70 68 D5 9 Existed 69 4 - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M70 68 Not existed 69
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between power window main switch harness connector and ground.
Power window main switch Ground Continuity Connector Terminal D5 7 Existed
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END