Diagnosis Procedure
- CHECK COMPONENT FUNCTION
With CONSULT
- Turn ignition switch ON. (Engine stopped.)
- On CONSULT screen, select "ENGINE" >> "ACTIVE TEST" >> "CHECK PURGING SWITCHOVER VALVE".
- Perform the Active Test.
- Check that the indicated value of "PWR CSMN (PURG SWOVR/V)" is between 390 - 495 mA.
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
GO TO STEP 2 .
- CHECK FUSE
- Turn ignition switch OFF.
- Check that No. 213 (15 A) fuse is not fusing.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace the fuse after repairing the applicable circuit.
- CHECK EVAP PURGE CONTROL VALVE POWER SUPPLY
- Insert the fuse which pulled out.
- Disconnect EVAP purge control valve harness connector.
- Turn ignition switch ON.
- Check the voltage between EVAP purge control valve harness connector and ground.
+ - Voltage EVAP purge control valve Connector Terminal E101 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
GO TO STEP 4 .
- CHECK EVAP PURGE CONTROL VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Pull out No. 213 fuse.
- Check the continuity between EVAP purge control valve harness connector and fuse terminal.
+ - Continuity EVAP purge control valve Connector Terminal E101 1 No. 213 fuse terminal Existed - Also check harness for short to ground.
Is the inspection result normal?
YES
Perform trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK EVAP PURGE CONTROL VALVE
Check EVAP purge control valve. Refer to COMPONENT INSPECTION (EVAP PURGE CONTROL VALVE) .
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Replace EVAP purge control valve. Refer to COMPONENT LOCATION .
- CHECK EVAP PURGE CONTROL VALVE CONTROL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and EVAP purge control valve harness connector.
+ - Continuity ECM EVAP purge control valve Connector Terminal Connector Terminal E48 153 E101 2 Existed - Also check harness for short to ground.
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace error-detected parts.
- CHECK EVAP PURGE CIRCUIT LEAKAGE
Check leakage of the following components.
- Hose and tube
- EVAP canister
- EVAP purge control valve (mechanical malfunction)
INSPECTION END