Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Infiniti >> 2017 >> QX30 Base >> Repair and Diagnosis >> Brakes >> Traction Control >> Brake Control System (Adaptive Brake) (ABR) (Introduction, Wiring Diagrams And Basic Inspection) >> Basic Inspection >> Calibration Of Acceleration Sensor >> Work Procedure

Work Procedure

CAUTION:

When the following operations are performed, always use CONSULT. (It cannot be performed by any means other than CONSULT.)

  1. CHECK THE VEHICLE STATUS

    The vehicle must be on a level surface.

    Do want to start calibration?

    YES 

    GO TO STEP 2  .

    NO 

    WORK END

  2. PERFORM CALIBRATION

    G-20 With CONSULT

    1. Select "ABS", "WORK SUPPORT", "Calibration of acceleration sensor" in this order.
    2. Touch "START".

    WORK END