Diagnosis Procedure
- CHECK POWER WINDOW MAIN SWITCH OUTPUT SIGNAL
- Turn ignition switch ON.
- Check signal between left front door control unit harness connector and ground using oscilloscope.
(+) (-) Condition Voltage
(approx.)Left front door control unit Connector Terminal D16 41 Ground Front power window LH Operating 12 V Other than above
Is the inspection result normal?
YES
INSPECTION END.
NO
GO TO STEP 2 .
- CHECK POWER WINDOW MAIN SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect power window main switch connector and left front door control unit connector.
- Check continuity between power window main switch harness connector and left front door control unit harness connector.
Power window main switch Left front door control unit Continuity Connector Terminal Connector Terminal D38 1 D16 41 Existed - Check continuity between power window main switch harness connector and ground.
Power window main switch Ground Continuity Connector Terminal D38 1 Not existed
Is the inspection result normal?
YES
Replace power window main switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.