Fail-Safe (Driver Side)
When a system malfunction is detected, deactivates a part of the system or all functions depending on the malfunctioning part.
When the malfunction condition recovers to the normal condition, the system returns to the normal operation.
| Display contents of CONSULT | Fail-safe |
|---|---|
| B2451: SEAT BLT MTR DR CIRC | Fully deactivates the whole operation. |
| B2452: SEAT BLT MTR AS CIRC | Deactivates a part of comfort function. |
| B2453: BR STROKE SEN CIRC | Stops the operation in the conditions as per the following.
|
| B2455: CONTROL UNIT DR | Stops the operation in the conditions as per the following. *
|
| B2457: CONTROL UNIT AS | Deactivates a part of comfort function. |
| B2458: LOCAL COMM | Deactivates a part of comfort function. |
| B2461: VHCL SPEED SIGNAL | Stops the operation in the conditions as per the following.
|
| B2466: DR/AS CONTROL UNIT | Deactivates a part of comfort function. |
| B2470: SYS HEAT PROTC DR |
|
| U0126: ST ANG SEN SIG | Stops the operation in the conditions as per the following.
|
| U0428: STRG ANGL CAL | Stops the operation in the conditions as per the following.
|
| U1000: CAN COMM CURCUIT | Stops the operation in the conditions as per the following. *
|
* : The deactivation mode differs depending on the internal malfunctioning condition of control unit