Inlet Port Memory Function: Description
When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.
Operating procedures for this trimmer are as per the following:
- Begin self-diagnosis STEP-5 mode. Refer to "DIAGNOSIS DESCRIPTION ".
- Press fan (UP:+) switch to set system in auxiliary mode.
- Press intake switch as desired.
AUTO INTAKE indicator REC indicator Setting status Setting changeover method FRE REC OFF ON AUTO control (Initial setting) Manual REC status is memorized. (Initial setting) Intake switch: ON ON ON Manual FRE status is memorized. Manual REC status is memorized. ON OFF Manual FRE status is memorized. AUTO control OFF OFF AUTO control AUTO control NOTE: When battery cable is disconnected or battery voltage is below 10 V, memory function is canceled. Memory function set becomes that of initial condition.