How To Set
WARNING: This page is about a different car, the 2011 Nissan 370Z. However, it is still accessible from the selected car via links, so may be relevant.
With CONSULT-III
Perform "TEMP SET CORRECT" of HVAC work support item.
WORK SUPPORT ITEMS REFERENCE
| Work support items | Display (°F) | Display (°C) |
|---|---|---|
| TEMP SET CORRECT | 6 | 3.0 |
| 5 | 2.5 | |
| 4 | 2.0 | |
| 3 | 1.5 | |
| 2 | 1.0 | |
| 1 | 0.5 | |
| 0 (initial status) | 0 (initial status) | |
| -1 | -0.5 | |
| -2 | -1.0 | |
| -3 | -1.5 | |
| -4 | -2.0 | |
| -5 | -2.5 | |
| -6 | -3.0 |
NOTE:
- When -3.0°C (-6°F) is corrected on the temperature setting set as 25.0°C (77°F), the temperature controlled by A/C auto amp. is 25.0°C (77°F) - 3.0°C (-6°F) = 22.0°C (72°F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.