Diagnosis Procedure
- CHECK ASCD STEERING SWITCH CIRCUIT
WITH CONSULT-III
- Turn ignition switch ON.
- Select "MAIN SW", "CANCEL SW", "RESUME/ACC SW" and "SET SW" in "DATA MONITOR" mode with CONSULT-III.
- Check each item indication under the following conditions.MONITOR ITEM CONDITION
Monitor item Condition Indication MAIN SW MAIN switch Pressed ON Released OFF CANCEL SW CANCEL switch Pressed ON Released OFF RESUME/ACC SW RESUME/ACCELERATE switch Pressed ON Released OFF SET SW SET/COAST switch Pressed ON Released OFF
WITHOUT CONSULT-III
- Turn ignition switch ON.
- Check the voltage between ECM harness connector terminals under the following conditions.VOLTAGE SPECIFICATION
ECM Condition Voltage (V) Connector + - Terminal Terminal E80 128 (ASCD steering switch signal) 130 MAIN switch: Pressed Approx. 0 CANCEL switch: Pressed Approx. 1 SET/COAST switch: Pressed Approx. 2 RESUME/ACCELERATE switch: Pressed Approx. 3 All ASCD steering switches: Released Approx. 4 Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 2.
- CHECK ASCD STEERING SWITCH GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Disconnect combination switch harness connector.
- Check the continuity between combination switch and ECM harness connector.CONTINUITY SPECIFICATION
Combination switch ECM Continuity Connector Terminal Connector Terminal - 32 E80 130 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Combination switch (spiral cable)
- Harness for open and short between ECM and combination switch
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ASCD STEERING SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between combination switch and ECM harness connector.CONTINUITY SPECIFICATION
Combination switch ECM Continuity Connector Terminal Connector Terminal - 25 E80 128 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- Check the continuity between combination switch and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Combination switch (spiral cable)
- Harness for open and short between ECM and combination switch
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ASCD STEERING SWITCH
Refer to "COMPONENT INSPECTION (ASCD STEERING SWITCH) ".
Is the inspection result normal?
YES: GO TO 7.
NO: Replace ASCD steering switch. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END