Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK PUSH-BUTTON IGNITION SWITCH OPERATION
Press push-button ignition switch and check if it turns to ON.
Does ignition switch turn to ON?
YES: GO TO 2.
NO: GO TO 4.
- CHECK IGNITION SWITCH OUTPUT SIGNAL (IPDM E/R)
- Disconnect push-button ignition switch connector.
- Check voltage between IPDM E/R harness connector and ground.TERMINAL VOLTAGE REFERENCE CHART
(+) (-) Voltage (V) (Approx.) IPDM E/R Connector Terminal E5 28 Ground Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (IPDM E/R)
- Disconnect IPDM E/R connector and BCM connector.
- Check continuity between IPDM E/R harness connector and push-button ignition switch harness connector.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R Push-button ignition switch Continuity Connector Terminal Connector Terminal E5 28 M50 4 Existed - Check continuity between IPDM E/R harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R Ground Continuity Connector Terminal E5 28 Not existed Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness or connector.
- CHECK IGNITION SWITCH OUTPUT SIGNAL (BCM)
- Disconnect push-button ignition switch connector.
- Check voltage between BCM harness connector and ground.
With steering lock unit
TERMINAL VOLTAGE REFERENCE CHART(+) (-) Voltage (V) (Approx.) BCM Connector Terminal M122 89 Ground Battery voltage Without steering lock unit
TERMINAL VOLTAGE REFERENCE CHART(+) (-) Voltage (V) (Approx.) BCM Connector Terminal M121 60 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (BCM)
- Disconnect BCM connector and IPDM E/R connector.
- Check continuity between BCM harness connector and push-button ignition switch harness connector.
With steering lock unit
TERMINAL CONTINUITY REFERENCE CHARTBCM Push-button ignition switch Continuity Connector Terminal Connector Terminal M122 89 M50 4 Existed Without steering lock unit
TERMINAL CONTINUITY REFERENCE CHARTBCM Push-button ignition switch Continuity Connector Terminal Connector Terminal M121 60 M50 4 Existed - Check continuity between BCM harness connector and ground.
With steering lock unit
TERMINAL CONTINUITY REFERENCE CHARTBCM Ground Continuity Connector Terminal M122 89 Not existed Without steering lock unit
TERMINAL CONTINUITY REFERENCE CHARTBCM Ground Continuity Connector Terminal M121 60 Not existed Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness or connector.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END