Diagnosis Procedure
- CHECK ECM POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check voltage between ECM terminal 121 and ground with CONSULT-III or tester.
Voltage: Battery voltage
OK or NG
OK: GO TO 3.
NG: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- IPDM E/R connector E121
- 20A fuse
- Harness for open or short between ECM and battery
Repair or replace harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "HOW TO CHECK TERMINAL " and "INTERMITTENT INCIDENT ".
OK or NG
OK: GO TO 4.
NG: Repair or replace harness or connectors.
- PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
- Turn ignition switch ON.
- Select "SELF DIAG RESULTS" mode with CONSULT-III.
- Touch "ERASE".
- Perform DTC Confirmation Procedure.
See "DTC CONFIRMATION PROCEDURE ".
- Is the 1st trip DTC P0603 displayed again?
With GST
- Turn ignition switch ON.
- Select Service $04 with GST.
- Perform DTC Confirmation Procedure.
See "DTC CONFIRMATION PROCEDURE ".
- Is the 1st trip DTC P0603 displayed again?
Yes or No
Yes: GO TO 5.
No: INSPECTION END
- REPLACE ECM
- Replace ECM.
- Perform initialization of IVIS(NATS) system and registration of all IVIS(NATS) ignition key IDs. Refer to "ECM RE-COMMUNICATING FUNCTION : SPECIAL REPAIR REQUIREMENT ".
- Perform "VIN REGISTRATION ".
- Perform "ACCELERATOR PEDAL RELEASED POSITION LEARNING ".
- Perform "THROTTLE VALVE CLOSED POSITION LEARNING ".
- Perform
"IDLE AIR VOLUME LEARNING
".
INSPECTION END