Diagnosis Procedure
- CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect exhaust valve timing control magnet retarder harness connector.
- Turn ignition switch ON.
- Check the voltage between exhaust valve timing control magnet retarder harness connector and ground.DTC CHART
DTC EVT control magnet retarder Ground Voltage Bank Connector Terminal P0078 1 F32 1 Ground Battery voltage P0084 2 F41 1
Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- Harness for open or short between exhaust valve timing control magnet retarder and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between exhaust valve timing control magnet retarder harness connector and ECM harness connector.DTC CHART
DTC EVT control magnet retarder ECM Continuity Bank Connector Terminal Connector Terminal P0078 1 F32 2 F101 6 Existed P0084 2 F41 2 7 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- REPLACE EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
- Replace malfunctioning exhaust valve timing control magnet retarder.
- Perform "EXHAUST VALVE TIMING CONTROL LEARNING : SPECIAL REPAIR REQUIREMENT ".
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END