DTC Detection Logic
DTC DETECTING CONDITION AND POSSIBLE CAUSE REFERENCE
| DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
|---|---|---|---|
| P0037 | Heated oxygen sensor 2 heater (bank 1) control circuit low | The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range. (An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
| P0038 | Heated oxygen sensor 2 heater (bank 1) control circuit high | The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range. (An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
| P0057 | Heated oxygen sensor 2 heater (bank 2) control circuit low | The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range. (An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
| P0058 | Heated oxygen sensor 2 heater (bank 2) control circuit high | The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range. (An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|