Terminals and Reference Value for Back Door Closure Control Unit
BACK DOOR CLOSURE CONTROL UNIT VOLTAGE SPECIFICATION
| Terminal | Wire color | Item | Signal Input/output | Condition | Voltage (V) (Approx.) | ||
|---|---|---|---|---|---|---|---|
| 1 | R | Power source (Fuse) | Input | - | Battery voltage | ||
| 2 | PU | Closure motor (open) signal | Output | Fully close → fully open | |||
| 3 | G | Closure motor (close) signal | Output | Fully open → fully close | |||
| 4 | B | Ground | - | - | 0 | ||
| 5 | W (B) | Ground(1) | - | - | 0(1) | ||
| Unlock sensor signal (passenger side) | Input | Passenger side door lock is locked | 5 | ||||
| Passenger side door lock is unlocked | 0 | ||||||
| 6 | Y (LG) | Back door opener switch signal | Input | Back door opener switch is ON | 0 | ||
| Other than above | 5 | ||||||
| 7 | OR | Half-latch switch signal | Input | Fully open → fully close | |||
| 8 | L | Close switch signal | Input | Fully open → fully close | |||
| 9 | P | Open switch signal | Input | Fully open → fully close | |||
|
|||||||