With Consult-II
- Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-II.
- Start engine and warm it up to the normal operating temperature.
- Maintain the following conditions for at least 6 consecutive seconds. Hold the accelerator pedal as steady as possible.CONDITION CHART
VHCL SPEED SE 100-120 km/h (63-75 MPH) ENG SPEED 2,000-4,000 rpm COOLAN TEMP/S 60-120°C (140-248°F) B/FUEL SCHDL More than 7.3 msec Selector lever D position - Stop vehicle with engine running and let engine idle for 10 seconds.
- If the 1st trip DTC is detected, go to
"DIAGNOSTIC PROCEDURE
".
If the 1st trip DTC is not detected, go to next step.
- Maintain the following conditions for at least 20 consecutive seconds.CONDITION CHART (20 CONSECUTIVE SECONDS)
ENG SPEED 1,700-3,175 rpm (A constant rotation is maintained.) COOLAN TEMP/S 70-105°C (158-221°F) Selector lever 1st or 2nd position Driving location uphill Driving vehicle uphill (Increased engine load will help maintain the driving conditions required for this test.) - If the 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE ".