2. Check Knock Sensor Input Signal Circuit For Open And Short-I
- Disconnect ECM harness connector.
- Check resistance between ECM terminals 125,126 and ground.
Refer to Wiring Diagram.
NOTE: It is necessary to use an ohmmeter which can measure more than 10 MΩ.- Resistance: Approximately 530 - 590kΩ [at 20°C (68°F)]
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 6. DETECT MALFUNCTIONING PART .
NG : GO TO 3.