1. Power Supply Circuit Check
- Turn ignition switch OFF.
- Disconnect trunk closure control unit connector.
- Check voltage between trunk closure control unit connector B56 terminal 2 and ground.
- 2 (PU) - Ground : Battery voltage
OK or NG
- OK : GO TO 2.
- NG : Check the following.
- 20A fuse [No. 15, located in the fuse block (J/B) No. 1].
- Harness for open or short between trunk closure control unit and fuse.